How to read a cycle analysis 01 Pick the cycle tab. Otto and Atkinson take a compression ratio r and heat input q<sub>in</sub> (or a peak temperature T₃); Diesel adds a cutoff ratio; Brayton takes a pressure ratio and turbine-inlet temperature; Carnot and Stirling take hot and cold reservoir temperatures. 02 Check the state table first. States are numbered in cycle order and the table shows p, T and v; the two constant-volume legs share a volume, the two isentropic legs sit between them. 03 Read work before efficiency. w<sub>net</sub> = q<sub>in</sub> − q<sub>out</sub> must close, and the engine checks it does; MEP = w<sub>net</sub>/(v<sub>max</sub> − v<sub>min</sub>) tells you how hard the cycle works per litre. 04 Compare with the Carnot bound. The same run reports 1 − T<sub>min</sub>/T<sub>max</sub> for its own extreme temperatures; the ratio of the two is the second-law efficiency. 05 Compare shapes. The strip below repeats Atkinson, Otto and Diesel at the same r and q<sub>in</sub>, which is where the naming arguments usually start.
Worked readouts Air with γ = 1.4, c<sub>v</sub> = 0.7175 kJ/(kg·K), intake 300 K and 100 kPa:
Cycle · input
Efficiency
Net work
Other
Otto · r = 8, q<sub>in</sub> = 1800 kJ/kg
56.4725 %
1016.5 kJ/kg
MEP 1349.3 kPa , T₃ 3197.91 K , Carnot 90.6189 %
Otto · r = 10
60.1893 %
1083.4 kJ/kg
MEP 1398.1 kPa
Otto · r = 16
67.0123 %
1206.2 kJ/kg
knock-limit warning above r ≈ 12
Diesel · r = 18, r<sub>c</sub> = 2 (q<sub>in</sub> ≈ 957.6 kJ/kg , T₃ ≈ 1906.6 K )
63.1578 %
604.8 kJ/kg
cutoff 2 , expansion ratio 9
Brayton · r<sub>p</sub> = 8, T₃ = 1300 K
44.7955 %
340.4 kJ/kg
back-work ratio 0.418
Carnot · 1000 K / 300 K
70.0000 %
220.7 kJ/kg
second-law efficiency 100 %
Stirling · 900 K / 300 K, r = 3
66.6667 %
189.2 kJ/kg
ε = 0.8 drops it to 51.1478 %
The Diesel row is fixed by its cutoff ratio rather than by q<sub>in</sub>: at r = 18, r<sub>c</sub> = 2 the constant-pressure burn sets q<sub>in</sub> = c<sub>p</sub>(T₃ − T₂) ≈ 957.6 kJ/kg with T₂ ≈ 953.3 K and T₃ ≈ 1906.6 K , so the 1800 kJ/kg of the Otto rows does not apply to it. The Otto states fill in the whole story: at r = 8 the compression takes the air from 100 kPa / 300 K to 1837.9 kPa / 689.2 K , constant-volume heating reaches 8527.8 kPa / 3197.9 K , and expansion returns it to 464.0 kPa / 1392.0 K at the original volume 0.8610 m³/kg . The comparison strip at r = 8 and q<sub>in</sub> = 1800 reads Atkinson 66.6369 % , Otto 56.4725 % , Diesel 40.0986 % .
Where efficiency comes from For any cold-air-standard cycle, efficiency is a function of temperature ratios, and those ratios are fixed by geometry. Otto is the purest case: both heat transfers are at constant volume, so η = 1 − r^(1−γ) and nothing else appears — not the heat input, not the intake temperature. At r = 8, 1 − 8^(−0.4) = 56.4725 % , and adding more heat raises T₃ without changing η. An ideal engine's efficiency is a property of its ratio; its work is a property of how much heat you add.
Diesel replaces constant-volume heating with constant-pressure heating, which leaves the gas hotter at the end of the burn and rejects more heat, so at equal r it is less efficient: 40.0986 % against Otto's 56.4725 % . Real diesels win because the absence of knock lets them run r = 15–20, and the r = 18 preset reaches 63.1578 % on that strength alone. Atkinson expands all the way back to intake pressure, recovering work Otto throws away, so at equal r it reads 66.6369 % . Brayton's ratio is a pressure ratio, not a volume ratio: 1 − r<sub>p</sub>^((1−γ)/γ) gives 44.7955 % at r<sub>p</sub> = 8. Losses enter through isentropic efficiencies (27.4106 % at η<sub>c</sub> = 0.8, η<sub>t</sub> = 0.85). In the lossless cycle, regeneration pre-heats the compressor exit to 682.8 K and lifts that cycle to 54.9117 % ; applied to the lossy cycle the same ε = 0.8 pre-heats to 764.9 K and reaches 35.6355 % .
Limits and edges
Constant specific heats, reversible processes. No combustion chemistry, no valve timing, no friction, no heat loss. The model is a teaching and comparison tool, not a fuel-consumption predictor. What it does not do. It does not model steam or refrigerant properties — that is the Real-fluid tab — and it does not simulate transients, turbochargers or knock beyond the r > 12 warning. Dynamic system models live in the Engineering Lab .
The ratio trap Three ratios look alike and mean different things. Otto's r = 8 is v₁/v₂ = 8, a volume ratio; Brayton's r<sub>p</sub> = 8 is a pressure ratio, and its efficiency is 44.7955 % , not 56.4725 % . Diesel's cutoff ratio r<sub>c</sub> = 2 is v₃/v₂, the extra expansion the constant-pressure burn creates — with r<sub>c</sub> → 1, Diesel converges to Otto. The comparison strip proves the ordering claim: at identical r and q<sub>in</sub>, Atkinson beats Otto beats Diesel, and Diesel's real-world advantage is the higher ratio it can run, not a better-shaped cycle. The Carnot bound closes the argument: the same run reports 90.6189 % for the r = 8 Otto temperature limits, so no amount of tuning that model can exceed it, and second-law efficiency compares designs honestly only at equal bounds.
Where it earns its place Checking textbook exercises State 1 at 100 kPa / 300 K, r = 8: the table gives T₂ = 689.2 K and p₂ = 1837.9 kPa , matching the standard cold-air answer. Efficiency 56.4725 % and MEP 1349.3 kPa come from the same run, so a homework set can be checked end to end.
Comparing hybrid and gas-turbine options Atkinson's 66.6369 % at r = 8 with only 485.8 kPa MEP shows why hybrids accept the lower power density. Regeneration taking Brayton from 44.7955 % to 54.9117 % without changing net work is the clearest single-lever demonstration in the tab.
Privacy All cycle states and plots are computed in your browser; nothing is uploaded.
References
Wikipedia, Otto cycle , en.wikipedia.org (访问日期:2026-10-07)— η = 1 − r^(1−γ) and the air-standard assumptions.
Wikipedia, Diesel cycle , en.wikipedia.org (访问日期:2026-10-07)— cutoff ratio and the r<sub>c</sub> → 1 limit.
Wikipedia, Brayton cycle , en.wikipedia.org (访问日期:2026-10-07)— pressure ratio, back work and regeneration.
Wikipedia, Carnot heat engine , en.wikipedia.org (访问日期:2026-10-07)— the temperature-limit bound used for every cycle.
Wikipedia, Mean effective pressure , en.wikipedia.org (访问日期:2026-10-07)— the work-per-swept-volume metric.
Calculators in this hub
Hand-picked tools, one click away. The mini versions compute live and carry your values into the full calculator.
Sources & review
Reviewed by CalcX Editorial Team