How to take a reading 01 Start measuring. Press the microphone button. 02 Pick a weighting. dB(A) for hearing-related levels, dB(C) for low-frequency content, dB(Z) unweighted. 03 Set the calibration offset. Match a reference meter on a steady source until the numbers agree. 04 Read Min, Max and Leq. The bar and big number are the current frame; the cards summarise the run. 05 Reset deliberately. Changing the weighting clears the statistics; Reset stats does the same.
Worked examples Frequency weighting at octave-band centres, from the meter's own curve:
Frequency
dB(A)
dB(C)
A − C
63 Hz
−26.22
−0.82
−25.40
125 Hz
−16.19
−0.17
−16.02
250 Hz
−8.68
−0.00
−8.67
500 Hz
−3.25
+0.03
−3.28
1 kHz
0.00
−0.00
0.00
2 kHz
+1.20
−0.17
+1.37
8 kHz
−1.15
−3.05
+1.90
A synthetic frame with a 1001.95 Hz tone at −30 dBFS reads Z −30.0 , A −29.99 and C −30.0 dBFS; with a calibration offset of 94 it shows 64.0 dB on all three scales. Leq over three equal stretches of 60, 70 and 80 dB is 75.68 dB — much closer to the loud stretch than to the average of the numbers.
What Leq averages Leq is an energy average: each frame returns to intensity, the intensities are averaged, and the result returns to decibels. That is why 60/70/80 dB over equal durations gives 75.68 dB , not 70. The same arithmetic gives source addition: two equal 70 dB sources sum to 73.01 dB , ten of them to 80.0 dB — 3.01 dB per doubling. The weighting buttons act earlier: dB(A) applies the IEC 61672 hearing curve, dB(C) is nearly flat, dB(Z) is unweighted.
Limits and what it does not do
An estimate, not a calibrated meter. A browser microphone reports full-scale dBFS with no absolute sensitivity, so the number is meaningful only after the offset is matched; there is no uncertainty budget, time weighting or octave-band analysis.
Weighting switches reset the run, so frames in different scales never share one average. What it does not do. It does not record audio, export a WAV or measure LUFS; for frequency detail use the Spectrum or Tuner panels.
The low-frequency gap At 63 Hz the A curve applies −26.22 dB where C applies −0.82 dB — the same rumble is 25.4 dB quieter on dB(A). At 8 kHz the sign flips: A sits 1.90 dB above C. A reading on one scale therefore says as much about the weighting as about the sound; leave it fixed for a run.
Where it is used Hearing exposure at home and at work The bar turns red at 85 dB — NIOSH's eight-hour limit — and the Leq card shows the energy average a shift delivered, not the loudest moment.
Checking playback equipment Play pink noise through a speaker and compare positions on the Leq card; dB(C) keeps the low end in the number instead of weighting it away.
Privacy Microphone audio is analysed in your browser in real time and never uploaded; only the calibration and weighting settings are remembered locally.
References
IEC, IEC 61672-1:2013, Sound level meters — Part 1 — A, C and Z weighting definitions. webstore.iec.ch (访问日期:2026-10-07)
Wikipedia, A-weighting — the IEC 61672 curve, 0 dB at 1 kHz. en.wikipedia.org (访问日期:2026-10-07)
Wikipedia, Sound pressure — the 20 µPa reference behind dB SPL. en.wikipedia.org (访问日期:2026-10-07)
CDC/NIOSH, About Noise and Hearing Loss — the 85 dBA eight-hour exposure limit. cdc.gov (访问日期:2026-10-07)
Wikipedia, Sound level meter — time weightings and meter classes. en.wikipedia.org (访问日期:2026-10-07)